Skip to content

Configuration

Remote Logger is set up from Settings > Devices & services > Add integration. There is no YAML configuration. The settings come in two groups:

  • Connection settings say where logs go. They are asked for when the entry is added, and changed later with Reconfigure on the entry's menu. A test log record is sent to check them before they are saved.
  • Event settings say what is sent. They are asked for after the connection settings, and changed later with Configure.

OpenTelemetry (OTLP) Connection

Logs are posted over HTTP to http(s)://<host>:<port><path>.

Setting Default Description
Collector host (required) Hostname or IP address of the OTLP collector.
Collector port 4318 HTTP port of the collector. gRPC (port 4317) isn't supported.
Use TLS (HTTPS) off Send over HTTPS. The collector's certificate is checked.
Payload encoding protobuf protobuf or json. Both are standard OTLP; use json if your collector only accepts that.
Batch max size 20 Records held before an early send, from 1 to 10000. See Sending Logs.
Custom resource attributes (none) Comma-separated key=value pairs added to the resource of every record, for example deployment.environment=production,service.namespace=home.
Token type bearer How the token is put in the Authorization header: bearer sends Bearer <token>; basic base64-encodes a username:password token; raw_basic sends Basic <token> with a token that is already encoded; api_key sends ApiKey <token>.
Access token (none) Optional token for the Authorization header. Use TLS when sending a token, or a repair issue is raised.
Additional headers (none) Extra HTTP headers, one Name: value per entry, for example stream-name: my-stream.
Logs endpoint path /v1/logs Path after host:port. Some services add a prefix, such as /api/otlp/v1/logs.
Client timeout 10 Seconds to wait for the collector, from 1 to 300.

If the collector answers HTTP 401 or 403, Home Assistant asks for a new token (re-authentication) and shows the entry as needing attention.

Syslog Connection

Messages use RFC 5424 format. Only one Syslog entry can be added.

Setting Default Description
Syslog server host (required) Hostname or IP address of the syslog server.
Syslog server port 514 Port of the syslog server.
Transport protocol udp udp sends and forgets; tcp keeps a connection and uses octet-counted framing (RFC 6587).
Use TLS (TCP only) off Encrypt the TCP connection. Not available with UDP.
CA certificate file (none) Path to a PEM file with the certificate authority for a private CA. Leave empty to use the system certificate store.
Client certificate file (none) Path to a PEM client certificate, for servers that require mutual TLS.
Client key file (none) Path to the PEM private key for the client certificate, if it isn't in the same file.
Application name homeassistant The APP-NAME field of each message.
Syslog facility local0 Facility used to work out the PRI value.
Batch max size 20 Messages held before an early send, from 1 to 10000. See Sending Logs.
Client timeout 10 Seconds to wait when connecting over TCP, from 1 to 300.
Strict RFC 5424 mode off Syslog-native output for receivers that check messages closely, such as Grafana Alloy. See Syslog.
Enterprise number 67614 IANA Private Enterprise Number for the strict mode SD-ID homeassistant@<number>. 32473 (RFC 5612) can be used for testing.

Event Settings

These are the same for both backends.

Setting Default Description
Use System Log events in place of Python root logger off Off: records are taken from Python's root logger, at or above the minimum log level. On: records come from the system_log_event event, which only carries warnings and errors, and needs fire_event: true under system_log: (see Event Based Logging).
Minimum log level INFO DEBUG, INFO, WARNING, ERROR or CRITICAL. Only used with the root logger.
Home Assistant lifecycle events off Start, started and stop events.
Home Assistant core change events off Components loaded, configuration and service changes, dashboards, themes and users.
Home Assistant core activity off Service calls, automations triggered and scripts started.
State changes, without attributes or context off Each state change with its old and new state only, and logbook entries.
State changes off Each state change in full, and logbook entries. Choose only one of the two state change options.
Serialize event data into log body off Puts the event data in the log body as JSON, keeping only entity_id, domain and service as attributes. Off, each data field is its own attribute, so a log database may make a column for every field.
Custom events (none) Other Home Assistant event names to send, one per entry, for example zha_event.
Suppress system_log_event as event name on Records from the system log are sent without an event name. Turn off when using Remote Logger as a general event recorder, so all event types can be told apart.

See Events for what each event group contains.

Sending Logs

Records are buffered in memory and sent in batches:

  • every 120 seconds;
  • sooner, when the buffer reaches the Batch max size;
  • when Home Assistant stops, or the entry is unloaded or reconfigured;
  • when the remote_logger.flush action is called.

If an OTLP collector can't be reached, or rejects a batch, that batch is dropped and counted by the Posting Errors sensor. Syslog messages that couldn't be sent are kept and retried on the next send. At most 10000 records are buffered; beyond that the oldest are dropped. A warning is logged once when the collector becomes unavailable, and an info message once when it can be reached again.

The diagnostic sensors are read from in-memory counters every 30 seconds.